Pressure Regulators

Relief Valves

Pressure control valves in cartridge as well as standalone configuration are produced, in direct operated, differential area and pilot operated configurations. Stable regulation fast response and low pressure drop features are FRC trademarks.

   
Specifications  
Fluid Specification All hydraulic oils, lubricants or fuels
Fluid Temperature -65°F to +275°F (-54°C to +135°C)
Air Temperature -65°F to +275°F (-54°C to +135°C)
Pressure Maximum Operating 6000 PSI (408 bar)
  Proof 9000 PSI (612 bar)
  Burst 12000 PSI (816 bar)
Mounting/Configuration Options Cartridge, Inline, Manifold, etc.
Normal System Pressure 100 to 6000 PSI (6.8 to 408 bar)
Minimum Flow 1 GPM (3.8 LPM))
Maximum Flow 70 GPM (265 LPM)
Outlet/Regulated Pressure As required up to 5700 PSI (388 bar)
 
       